Ubuntu Pastebin

Paste from root at Fri, 30 Jan 2015 19:54:13 +0000

Download as text
  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-59-generic] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda ES.2
Device Model:     ST31000340NS
Serial Number:    9QJ0FGH4
LU WWN Device Id: 5 000c50 00988dda2
Firmware Version: SN06
User Capacity:    1,000,204,886,016 bytes [1.00 TB]
Sector Size:      512 bytes logical/physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Fri Jan 30 12:54:12 2015 MST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (  73)	The previous self-test completed having
					a test element that failed and the test
					element that failed is not known.
Total time to complete Offline 
data collection: 		(  642) seconds.
Offline data collection
capabilities: 			 (0x7b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 ( 228) minutes.
Conveyance self-test routine
recommended polling time: 	 (   2) minutes.
SCT capabilities: 	       (0x103d)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   083   053   006    Pre-fail  Always       -       222685962
  3 Spin_Up_Time            0x0003   099   098   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       92
  5 Reallocated_Sector_Ct   0x0033   028   028   036    Pre-fail  Always   FAILING_NOW 1483
  7 Seek_Error_Rate         0x000f   079   072   030    Pre-fail  Always       -       84178230
  9 Power_On_Hours          0x0032   055   055   000    Old_age   Always       -       39526
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   037   020    Old_age   Always       -       51
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   001   001   000    Old_age   Always       -       903
188 Command_Timeout         0x0032   100   098   000    Old_age   Always       -       8590065667
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   070   049   045    Old_age   Always       -       30 (Min/Max 27/30)
194 Temperature_Celsius     0x0022   030   051   000    Old_age   Always       -       30 (0 20 0 0)
195 Hardware_ECC_Recovered  0x001a   052   021   000    Old_age   Always       -       222685962
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0

SMART Error Log Version: 1
ATA Error Count: 6 (device log contains only the most recent five errors)
	CR = Command Register [HEX]
	FR = Features Register [HEX]
	SC = Sector Count Register [HEX]
	SN = Sector Number Register [HEX]
	CL = Cylinder Low Register [HEX]
	CH = Cylinder High Register [HEX]
	DH = Device/Head Register [HEX]
	DC = Device Command Register [HEX]
	ER = Error register [HEX]
	ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 6 occurred at disk power-on lifetime: 36067 hours (1502 days + 19 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 08 ff ff ff 4f 00  43d+07:54:29.596  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00  43d+07:54:29.596  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00  43d+07:54:29.595  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00  43d+07:54:29.595  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00  43d+07:54:29.595  READ FPDMA QUEUED

Error 5 occurred at disk power-on lifetime: 36067 hours (1502 days + 19 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 f8 ff ff ff 4f 00  43d+07:54:25.013  READ FPDMA QUEUED
  60 00 10 ff ff ff 4f 00  43d+07:54:25.002  READ FPDMA QUEUED
  60 00 f8 ff ff ff 4f 00  43d+07:54:24.986  READ FPDMA QUEUED
  60 00 f8 ff ff ff 4f 00  43d+07:54:24.967  READ FPDMA QUEUED
  60 00 f8 ff ff ff 4f 00  43d+07:54:24.881  READ FPDMA QUEUED

Error 4 occurred at disk power-on lifetime: 7614 hours (317 days + 6 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  08 51 00 00 00 00 00  Error: 

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  2f 00 02 ff ff ff 0f 00      00:06:34.285  READ LOG EXT
  3f 00 01 ff ff ff 0f 00      00:06:34.283  WRITE LOG EXT
  ef 03 45 00 00 00 00 00      00:06:34.233  SET FEATURES [Set transfer mode]
  00 00 00 00 00 00 00 04      00:06:34.183  NOP [Abort queued commands]
  2f 00 01 ff ff ff 0f 00      00:06:33.922  READ LOG EXT

Error 3 occurred at disk power-on lifetime: 7614 hours (317 days + 6 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  08 51 00 00 00 00 00  Error: 

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  2f 00 01 ff ff ff 0f 00      00:06:33.922  READ LOG EXT
  3f 00 01 ff ff ff 0f 00      00:06:33.921  WRITE LOG EXT
  92 03 01 00 00 00 a0 00      00:02:56.233  DOWNLOAD MICROCODE [Reserved subcommand]
  ec 00 01 00 00 00 00 00      00:02:56.230  IDENTIFY DEVICE
  ef 03 45 00 00 00 00 00      00:02:56.180  SET FEATURES [Set transfer mode]

Error 2 occurred at disk power-on lifetime: 7614 hours (317 days + 6 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  08 51 00 00 00 00 00  Error: 

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  2f 00 02 ff ff ff 0f 00      00:02:55.870  READ LOG EXT
  3f 00 01 ff ff ff 0f 00      00:02:55.860  WRITE LOG EXT
  ef 03 45 00 00 00 00 00      00:02:55.810  SET FEATURES [Set transfer mode]
  00 00 00 00 00 00 00 04      00:02:55.755  NOP [Abort queued commands]
  2f 00 01 ff ff ff 0f 00      00:02:55.494  READ LOG EXT

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed: unknown failure    90%     39308         0

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Download as text