Ubuntu Pastebin

Paste from mitchell at Sat, 25 Feb 2017 00:41:37 +0000

Download as text
  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.4.0-62-generic-tuxonice] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     SAMSUNG SpinPoint M7E (AF)
Device Model:     SAMSUNG HM321HI
Serial Number:    S25WJ9CZA06424
LU WWN Device Id: 5 0024e9 2039ada44
Firmware Version: 2AJ10001
User Capacity:    320,072,933,376 bytes [320 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    5400 rpm
Form Factor:      2.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 6
SATA Version is:  SATA 2.6, 3.0 Gb/s
Local Time is:    Fri Feb 24 19:41:36 2017 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00)	Offline data collection activity
					was never started.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      ( 121)	The previous self-test completed having
					the read element of the test failed.
Total time to complete Offline 
data collection: 		( 4920) seconds.
Offline data collection
capabilities: 			 (0x51) SMART execute Offline immediate.
					No Auto Offline data collection support.
					Suspend Offline collection upon new
					command.
					No Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 (  82) minutes.
SCT capabilities: 	       (0x003f)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   100   100   051    Pre-fail  Always       -       253
  2 Throughput_Performance  0x0027   252   252   000    Pre-fail  Always       -       0
  3 Spin_Up_Time            0x0023   089   088   025    Pre-fail  Always       -       3517
  4 Start_Stop_Count        0x0032   095   095   000    Old_age   Always       -       5732
  5 Reallocated_Sector_Ct   0x0033   252   252   010    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x002f   252   252   051    Pre-fail  Always       -       0
  8 Seek_Time_Performance   0x0025   252   252   015    Pre-fail  Offline      -       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -       4950
 10 Spin_Retry_Count        0x0033   252   252   051    Pre-fail  Always       -       0
 11 Calibration_Retry_Count 0x0032   100   100   000    Old_age   Always       -       618
 12 Power_Cycle_Count       0x0032   095   095   000    Old_age   Always       -       5793
183 Runtime_Bad_Block       0x0032   100   100   010    Old_age   Always       -       17
184 End-to-End_Error        0x0033   252   252   097    Pre-fail  Always       -       0
186 Unknown_Attribute       0x0032   252   252   000    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       172
188 Command_Timeout         0x0032   252   252   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0002   065   041   040    Old_age   Always       -       35 (Min/Max 12/59)
191 G-Sense_Error_Rate      0x0022   100   100   000    Old_age   Always       -       7005
192 Power-Off_Retract_Count 0x0022   252   252   000    Old_age   Always       -       0
193 Load_Cycle_Count        0x0032   095   095   000    Old_age   Always       -       57807
194 Temperature_Celsius     0x0002   064   041   000    Old_age   Always       -       35 (Min/Max 12/59)
195 Hardware_ECC_Recovered  0x003a   100   100   000    Old_age   Always       -       0
196 Reallocated_Event_Count 0x0032   252   252   000    Old_age   Always       -       0
197 Current_Pending_Sector  0x0032   100   100   000    Old_age   Always       -       9
198 Offline_Uncorrectable   0x0030   252   252   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0036   100   100   000    Old_age   Always       -       4
200 Multi_Zone_Error_Rate   0x002a   100   100   000    Old_age   Always       -       719

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed: read failure       90%      4950         247534441
# 2  Short offline       Completed: read failure       90%      4950         247534441

SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Completed_read_failure [90% left] (0-65535)
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Download as text