smartctl 6.4 2014-10-07 r4002 [x86_64-linux-4.2.0-22-generic] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

Warning! Drive Identity Structure error: invalid SMART checksum.
=== START OF INFORMATION SECTION ===
Device Model:     wDc wD1200jB-00FuA0
Serial Number:    wD-WcAeS1143024
Firmware Version: 15.05R15
User Capacity:    18,014,793,425,707,008 bytes [18.0 PB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    8192 rpm
Form Factor:      Unknown (0x2000)
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   Unknown(0x207e) (unknown minor revision code: 0x2000)
Local Time is:    Wed Dec 23 14:25:53 2015 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

Warning! SMART Attribute Data Structure error: invalid SMART checksum.
Warning! SMART Attribute Thresholds Structure error: invalid SMART checksum.
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (  32)	The self-test routine was interrupted
					by the host with a hard or soft reset.
Total time to complete Offline 
data collection: 		(12551) seconds.
Offline data collection
capabilities: 			 (0x79) SMART execute Offline immediate.
					No Auto Offline data collection support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x2003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					No General Purpose Logging support.
Short self-test routine 
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 (  59) minutes.
Conveyance self-test routine
recommended polling time: 	 (   5) minutes.

SMART Attributes Data Structure revision number: 8208
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002b   232   200   051    Pre-fail  Always       -       137441050656
  3 Spin_Up_Time            0x0027   169   139   053    Pre-fail  Always       -       2082 (Average 32)
  4 Start_Stop_Count        0x0032   120   088   040    Old_age   Always       -       137441063211
  5 Reallocated_Sector_Ct   0x0033   232   200   172    Pre-fail  Always       -       32 (32 32)
  7 Seek_Error_Rate         0x002b   232   200   051    Pre-fail  Always       -       137441050656
  9 Power_On_Hours          0x0032   120   088   032    Old_age   Always       -       2106613 (0 32 0)
 10 Spin_Retry_Count        0x0033   100   100   051    Pre-fail  Always       -       137441050656
 11 Calibration_Retry_Count 0x0033   100   100   051    Pre-fail  Always       -       137441050656
 12 Power_Cycle_Count       0x0032   100   100   032    Old_age   Always       -       137441051114
194 Temperature_Celsius     0x0022   108   253   032    Old_age   Always       -       42 (0 32 0 32 0)
196 Reallocated_Event_Count 0x0032   232   200   032    Old_age   Always       -       32 (32 32)
197 Current_Pending_Sector  0x0032   232   200   032    Old_age   Always       -       137441050656
198 Offline_Uncorrectable   0x0032   232   200   032    Old_age   Always       -       137441050656
199 UDMA_CRC_Error_Count    0x002a   232   253   032    Old_age   Always       -       137441053617
200 Multi_Zone_Error_Rate   0x0029   232   155   051    Pre-fail  Offline      -       137441050656

Warning! SMART ATA Error Log Structure error: invalid SMART checksum.
SMART Error Log Version: 1
Invalid Error Log index = 0x20 (T13/1321D rev 1c Section 8.41.6.8.2.2 gives valid range from 1 to 5)

Warning! SMART Self-Test Log Structure error: invalid SMART checksum.
SMART Self-test log structure revision number 8193
Warning: ATA Specification requires self-test log structure revision number = 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
SMART Selective self-test log data structure revision number 8193
Note: revision number not 1 implies that no selective self-test has ever been run
 SPAN              MIN_LBA              MAX_LBA  CURRENT_TEST_STATUS
    1  2305878194122661888  2305878194122661888  Not_testing
    2  2305878194122661888  2305878194122661888  Not_testing
    3  2305878194122661888  2305878194122661888  Not_testing
    4  2305878194122661888  2305878194122661888  Not_testing
    5  2305878194122661888  2305878194122661888  Not_testing
 8192  2305878194122661888  2305878194122727423  Read_scanning was completed without error
Selective self-test flags (0x2000):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 8192 minute delay.