1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197 | smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.0-71-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Hitachi/HGST Travelstar Z7K500
Device Model: HGST HTS725050A7E630
Serial Number: TF655AY91GNHHL
LU WWN Device Id: 5 000cca 76cd4c1a7
Firmware Version: GH2ZB550
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Dec 3 11:15:12 2015 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 45) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 90) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 090 090 062 Pre-fail Always - 61
2 Throughput_Performance 0x0005 100 100 040 Pre-fail Offline - 0
3 Spin_Up_Time 0x0007 225 225 033 Pre-fail Always - 1
4 Start_Stop_Count 0x0012 099 099 000 Old_age Always - 2117
5 Reallocated_Sector_Ct 0x0033 082 082 005 Pre-fail Always - 0
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
8 Seek_Time_Performance 0x0005 100 100 040 Pre-fail Offline - 0
9 Power_On_Hours 0x0012 088 088 000 Old_age Always - 5632
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 2063
191 G-Sense_Error_Rate 0x000a 100 100 000 Old_age Always - 0
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 4294901878
193 Load_Cycle_Count 0x0012 085 085 000 Old_age Always - 156044
194 Temperature_Celsius 0x0002 146 146 000 Old_age Always - 41 (Min/Max 9/55)
196 Reallocated_Event_Count 0x0032 079 079 000 Old_age Always - 680
197 Current_Pending_Sector 0x0022 093 093 000 Old_age Always - 384
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 7
223 Load_Retry_Count 0x000a 100 100 000 Old_age Always - 0
SMART Error Log Version: 1
ATA Error Count: 3297 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 3297 occurred at disk power-on lifetime: 5477 hours (228 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 c0 f8 9b fd 09 Error: UNC at LBA = 0x09fd9bf8 = 167615480
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 c0 b8 9b fd 40 00 01:51:37.195 READ FPDMA QUEUED
61 18 b8 a8 79 48 40 00 01:51:37.105 WRITE FPDMA QUEUED
61 10 b0 10 79 48 40 00 01:51:36.969 WRITE FPDMA QUEUED
61 e0 a8 60 77 48 40 00 01:51:36.968 WRITE FPDMA QUEUED
60 80 a0 f0 f3 79 40 00 01:51:36.968 READ FPDMA QUEUED
Error 3296 occurred at disk power-on lifetime: 5477 hours (228 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 c0 f8 9b fd 09 Error: UNC at LBA = 0x09fd9bf8 = 167615480
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 70 b8 9b fd 40 00 01:51:32.709 READ FPDMA QUEUED
61 80 68 88 4b 73 40 00 01:51:32.664 WRITE FPDMA QUEUED
61 00 60 88 4a 73 40 00 01:51:32.664 WRITE FPDMA QUEUED
61 00 58 88 49 73 40 00 01:51:32.664 WRITE FPDMA QUEUED
61 00 50 88 48 73 40 00 01:51:32.664 WRITE FPDMA QUEUED
Error 3295 occurred at disk power-on lifetime: 5477 hours (228 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 c0 f8 9b fd 09 Error: UNC at LBA = 0x09fd9bf8 = 167615480
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 18 b8 9b fd 40 00 01:51:27.479 READ FPDMA QUEUED
61 30 10 e0 54 05 40 00 01:51:27.074 WRITE FPDMA QUEUED
61 00 08 e0 53 05 40 00 01:51:27.074 WRITE FPDMA QUEUED
61 00 f8 e0 52 05 40 00 01:51:27.074 WRITE FPDMA QUEUED
61 00 f0 e0 51 05 40 00 01:51:27.074 WRITE FPDMA QUEUED
Error 3294 occurred at disk power-on lifetime: 5477 hours (228 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 c0 f8 9b fd 09 Error: UNC at LBA = 0x09fd9bf8 = 167615480
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 08 b8 9b fd 40 00 01:51:23.610 READ FPDMA QUEUED
61 08 f8 00 89 66 40 00 01:51:23.592 WRITE FPDMA QUEUED
60 00 f0 b8 9c fd 40 00 01:51:23.592 READ FPDMA QUEUED
60 00 e8 b8 9d fd 40 00 01:51:23.592 READ FPDMA QUEUED
60 00 e0 b8 9e fd 40 00 01:51:23.592 READ FPDMA QUEUED
Error 3293 occurred at disk power-on lifetime: 5477 hours (228 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 c0 f8 9b fd 09 Error: UNC at LBA = 0x09fd9bf8 = 167615480
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 a0 b8 9e fd 40 00 01:51:20.218 READ FPDMA QUEUED
60 00 98 b8 9d fd 40 00 01:51:20.218 READ FPDMA QUEUED
60 00 90 b8 9c fd 40 00 01:51:20.218 READ FPDMA QUEUED
60 00 88 b8 9b fd 40 00 01:51:20.218 READ FPDMA QUEUED
60 00 80 b8 9a fd 40 00 01:51:20.217 READ FPDMA QUEUED
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0x50) Completed without error 00% 2610 -
# 2 Short offline Completed without error 00% 2610 -
# 3 Short offline Aborted by host 30% 2068 -
# 4 Vendor (0x50) Completed without error 00% 32 -
# 5 Short offline Completed without error 00% 32 -
# 6 Vendor (0x50) Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
|