Ubuntu Pastebin

Paste from mastershake at Thu, 3 Dec 2015 16:15:14 +0000

Download as text
  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.0-71-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Hitachi/HGST Travelstar Z7K500
Device Model:     HGST HTS725050A7E630
Serial Number:    TF655AY91GNHHL
LU WWN Device Id: 5 000cca 76cd4c1a7
Firmware Version: GH2ZB550
User Capacity:    500,107,862,016 bytes [500 GB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    7200 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 6
SATA Version is:  SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Thu Dec  3 11:15:12 2015 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00)	Offline data collection activity
					was never started.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(   45) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 (  90) minutes.
SCT capabilities: 	       (0x003d)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   090   090   062    Pre-fail  Always       -       61
  2 Throughput_Performance  0x0005   100   100   040    Pre-fail  Offline      -       0
  3 Spin_Up_Time            0x0007   225   225   033    Pre-fail  Always       -       1
  4 Start_Stop_Count        0x0012   099   099   000    Old_age   Always       -       2117
  5 Reallocated_Sector_Ct   0x0033   082   082   005    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always       -       0
  8 Seek_Time_Performance   0x0005   100   100   040    Pre-fail  Offline      -       0
  9 Power_On_Hours          0x0012   088   088   000    Old_age   Always       -       5632
 10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   099   099   000    Old_age   Always       -       2063
191 G-Sense_Error_Rate      0x000a   100   100   000    Old_age   Always       -       0
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       4294901878
193 Load_Cycle_Count        0x0012   085   085   000    Old_age   Always       -       156044
194 Temperature_Celsius     0x0002   146   146   000    Old_age   Always       -       41 (Min/Max 9/55)
196 Reallocated_Event_Count 0x0032   079   079   000    Old_age   Always       -       680
197 Current_Pending_Sector  0x0022   093   093   000    Old_age   Always       -       384
198 Offline_Uncorrectable   0x0008   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x000a   200   200   000    Old_age   Always       -       7
223 Load_Retry_Count        0x000a   100   100   000    Old_age   Always       -       0

SMART Error Log Version: 1
ATA Error Count: 3297 (device log contains only the most recent five errors)
	CR = Command Register [HEX]
	FR = Features Register [HEX]
	SC = Sector Count Register [HEX]
	SN = Sector Number Register [HEX]
	CL = Cylinder Low Register [HEX]
	CH = Cylinder High Register [HEX]
	DH = Device/Head Register [HEX]
	DC = Device Command Register [HEX]
	ER = Error register [HEX]
	ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 3297 occurred at disk power-on lifetime: 5477 hours (228 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 c0 f8 9b fd 09  Error: UNC at LBA = 0x09fd9bf8 = 167615480

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 c0 b8 9b fd 40 00      01:51:37.195  READ FPDMA QUEUED
  61 18 b8 a8 79 48 40 00      01:51:37.105  WRITE FPDMA QUEUED
  61 10 b0 10 79 48 40 00      01:51:36.969  WRITE FPDMA QUEUED
  61 e0 a8 60 77 48 40 00      01:51:36.968  WRITE FPDMA QUEUED
  60 80 a0 f0 f3 79 40 00      01:51:36.968  READ FPDMA QUEUED

Error 3296 occurred at disk power-on lifetime: 5477 hours (228 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 c0 f8 9b fd 09  Error: UNC at LBA = 0x09fd9bf8 = 167615480

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 70 b8 9b fd 40 00      01:51:32.709  READ FPDMA QUEUED
  61 80 68 88 4b 73 40 00      01:51:32.664  WRITE FPDMA QUEUED
  61 00 60 88 4a 73 40 00      01:51:32.664  WRITE FPDMA QUEUED
  61 00 58 88 49 73 40 00      01:51:32.664  WRITE FPDMA QUEUED
  61 00 50 88 48 73 40 00      01:51:32.664  WRITE FPDMA QUEUED

Error 3295 occurred at disk power-on lifetime: 5477 hours (228 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 c0 f8 9b fd 09  Error: UNC at LBA = 0x09fd9bf8 = 167615480

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 18 b8 9b fd 40 00      01:51:27.479  READ FPDMA QUEUED
  61 30 10 e0 54 05 40 00      01:51:27.074  WRITE FPDMA QUEUED
  61 00 08 e0 53 05 40 00      01:51:27.074  WRITE FPDMA QUEUED
  61 00 f8 e0 52 05 40 00      01:51:27.074  WRITE FPDMA QUEUED
  61 00 f0 e0 51 05 40 00      01:51:27.074  WRITE FPDMA QUEUED

Error 3294 occurred at disk power-on lifetime: 5477 hours (228 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 c0 f8 9b fd 09  Error: UNC at LBA = 0x09fd9bf8 = 167615480

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 08 b8 9b fd 40 00      01:51:23.610  READ FPDMA QUEUED
  61 08 f8 00 89 66 40 00      01:51:23.592  WRITE FPDMA QUEUED
  60 00 f0 b8 9c fd 40 00      01:51:23.592  READ FPDMA QUEUED
  60 00 e8 b8 9d fd 40 00      01:51:23.592  READ FPDMA QUEUED
  60 00 e0 b8 9e fd 40 00      01:51:23.592  READ FPDMA QUEUED

Error 3293 occurred at disk power-on lifetime: 5477 hours (228 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 c0 f8 9b fd 09  Error: UNC at LBA = 0x09fd9bf8 = 167615480

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 a0 b8 9e fd 40 00      01:51:20.218  READ FPDMA QUEUED
  60 00 98 b8 9d fd 40 00      01:51:20.218  READ FPDMA QUEUED
  60 00 90 b8 9c fd 40 00      01:51:20.218  READ FPDMA QUEUED
  60 00 88 b8 9b fd 40 00      01:51:20.218  READ FPDMA QUEUED
  60 00 80 b8 9a fd 40 00      01:51:20.217  READ FPDMA QUEUED

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Vendor (0x50)       Completed without error       00%      2610         -
# 2  Short offline       Completed without error       00%      2610         -
# 3  Short offline       Aborted by host               30%      2068         -
# 4  Vendor (0x50)       Completed without error       00%        32         -
# 5  Short offline       Completed without error       00%        32         -
# 6  Vendor (0x50)       Completed without error       00%         0         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Download as text