Ubuntu Pastebin

Paste from e at Tue, 29 Sep 2015 14:20:01 +0000

Download as text
  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.0-65-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Hitachi/HGST Travelstar 5K750
Device Model:     Hitachi HTS547575A9E384
Serial Number:    J2540059FDHAUE
LU WWN Device Id: 5 000cca 6dfeff495
Firmware Version: JE4OA50A
User Capacity:    750,156,374,016 bytes [750 GB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    5400 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 6
SATA Version is:  SATA 2.6, 3.0 Gb/s
Local Time is:    Tue Sep 29 17:19:57 2015 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(   45) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 ( 194) minutes.
SCT capabilities: 	       (0x003d)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   100   098   062    Pre-fail  Always       -       0
  2 Throughput_Performance  0x0025   198   100   040    Pre-fail  Offline      -       135
  3 Spin_Up_Time            0x0023   243   100   033    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   098   098   000    Old_age   Always       -       3575
  5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail  Always       -       24 (0 3)
  7 Seek_Error_Rate         0x002f   100   100   067    Pre-fail  Always       -       0
  8 Seek_Time_Performance   0x0025   117   100   040    Pre-fail  Offline      -       33
  9 Power_On_Hours          0x0032   062   062   000    Old_age   Always       -       16728
 10 Spin_Retry_Count        0x0033   100   100   060    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   099   099   000    Old_age   Always       -       2112
183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always       -       0
184 End-to-End_Error        0x0033   100   100   097    Pre-fail  Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       339357007872
188 Command_Timeout         0x0032   100   098   000    Old_age   Always       -       38661652512
190 Airflow_Temperature_Cel 0x0022   056   042   045    Old_age   Always   In_the_past 44 (Min/Max 39/44)
191 G-Sense_Error_Rate      0x0032   063   063   000    Old_age   Always       -       9694
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       3866683
193 Load_Cycle_Count        0x0032   009   009   000    Old_age   Always       -       917058
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       5
197 Current_Pending_Sector  0x0032   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0030   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0036   100   100   000    Old_age   Always       -       0
223 Load_Retry_Count        0x002a   100   100   000    Old_age   Always       -       0

SMART Error Log Version: 1
ATA Error Count: 26 (device log contains only the most recent five errors)
	CR = Command Register [HEX]
	FR = Features Register [HEX]
	SC = Sector Count Register [HEX]
	SN = Sector Number Register [HEX]
	CL = Cylinder Low Register [HEX]
	CH = Cylinder High Register [HEX]
	DH = Device/Head Register [HEX]
	DC = Device Command Register [HEX]
	ER = Error register [HEX]
	ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 26 occurred at disk power-on lifetime: 16707 hours (696 days + 3 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 20 30 bf 09  Error: WP at LBA = 0x09bf3020 = 163524640

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  61 00 18 00 10 ce 40 00   2d+21:03:13.191  WRITE FPDMA QUEUED
  61 00 10 00 0c ce 40 00   2d+21:03:12.851  WRITE FPDMA QUEUED
  61 00 08 00 08 ce 40 00   2d+21:03:12.671  WRITE FPDMA QUEUED
  61 00 00 00 04 ce 40 00   2d+21:03:12.671  WRITE FPDMA QUEUED
  61 00 f0 00 00 ce 40 00   2d+21:03:12.609  WRITE FPDMA QUEUED

Error 25 occurred at disk power-on lifetime: 16707 hours (696 days + 3 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 41 08 80 f7 2d 07  Error: UNC at LBA = 0x072df780 = 120452992

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 d0 a0 d0 2b 40 00   2d+21:02:24.325  READ FPDMA QUEUED
  61 00 c8 00 69 b7 40 00   2d+21:02:24.242  WRITE FPDMA QUEUED
  61 00 c0 00 65 b7 40 00   2d+21:02:24.241  WRITE FPDMA QUEUED
  61 00 b8 00 61 b7 40 00   2d+21:02:24.203  WRITE FPDMA QUEUED
  61 00 b0 00 5d b7 40 00   2d+21:02:24.010  WRITE FPDMA QUEUED

Error 24 occurred at disk power-on lifetime: 16461 hours (685 days + 21 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 58 30 ff 0a  Error: WP at LBA = 0x0aff3058 = 184496216

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  61 00 10 00 2c 2b 40 00   1d+15:20:01.827  WRITE FPDMA QUEUED
  61 00 08 00 28 2b 40 00   1d+15:20:01.645  WRITE FPDMA QUEUED
  61 00 00 00 24 2b 40 00   1d+15:20:01.561  WRITE FPDMA QUEUED
  61 00 f0 00 20 2b 40 00   1d+15:20:01.334  WRITE FPDMA QUEUED
  61 00 e8 00 1c 2b 40 00   1d+15:20:01.151  WRITE FPDMA QUEUED

Error 23 occurred at disk power-on lifetime: 16461 hours (685 days + 21 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 70 7d 84 01  Error: WP at LBA = 0x01847d70 = 25460080

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  61 00 00 00 44 0b 40 00   1d+15:17:45.219  WRITE FPDMA QUEUED
  61 00 f0 00 40 0b 40 00   1d+15:17:45.004  WRITE FPDMA QUEUED
  61 00 e8 00 3c 0b 40 00   1d+15:17:44.919  WRITE FPDMA QUEUED
  61 00 e0 00 38 0b 40 00   1d+15:17:44.915  WRITE FPDMA QUEUED
  61 00 d8 00 34 0b 40 00   1d+15:17:44.877  WRITE FPDMA QUEUED

Error 22 occurred at disk power-on lifetime: 16461 hours (685 days + 21 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 10 28 33 aa 04  Error: WP at LBA = 0x04aa3328 = 78263080

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  61 00 b8 00 54 ea 40 00   1d+15:16:01.828  WRITE FPDMA QUEUED
  61 00 b0 00 50 ea 40 00   1d+15:16:01.700  WRITE FPDMA QUEUED
  61 00 a8 00 4c ea 40 00   1d+15:16:01.660  WRITE FPDMA QUEUED
  61 00 a0 00 48 ea 40 00   1d+15:16:01.654  WRITE FPDMA QUEUED
  61 00 98 00 44 ea 40 00   1d+15:16:01.625  WRITE FPDMA QUEUED

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%     16715         -
# 2  Extended offline    Completed without error       00%     16712         -
# 3  Short offline       Completed without error       00%      9676         -
# 4  Short offline       Aborted by host               60%      5695         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Download as text