Ubuntu Pastebin

Paste from limberian at Sat, 15 Aug 2015 01:46:05 +0000

Download as text
  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.19.0-15-generic] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.12
Device Model:     ST31000528AS
Serial Number:    9VPDVBCR
LU WWN Device Id: 5 000c50 0364f3668
Firmware Version: CC46
User Capacity:    1.000.204.886.016 bytes [1,00 TB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    7200 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 2.6, 3.0 Gb/s
Local Time is:    Sat Aug 15 04:46:04 2015 EEST

==> WARNING: A firmware update for this drive may be available,
see the following Seagate web pages:
http://knowledge.seagate.com/articles/en_US/FAQ/207931en
http://knowledge.seagate.com/articles/en_US/FAQ/213891en

SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(  609) seconds.
Offline data collection
capabilities: 			 (0x7b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 ( 174) minutes.
Conveyance self-test routine
recommended polling time: 	 (   2) minutes.
SCT capabilities: 	       (0x103f)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   109   099   006    Pre-fail  Always       -       21335218
  3 Spin_Up_Time            0x0003   095   094   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   096   096   020    Old_age   Always       -       4825
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   087   060   030    Pre-fail  Always       -       505117944
  9 Power_On_Hours          0x0032   080   080   000    Old_age   Always       -       17737
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   098   098   020    Old_age   Always       -       2403
183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always       -       0
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   001   001   000    Old_age   Always       -       241
188 Command_Timeout         0x0032   100   100   000    Old_age   Always       -       1
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   059   054   045    Old_age   Always       -       41 (Min/Max 37/42)
194 Temperature_Celsius     0x0022   041   046   000    Old_age   Always       -       41 (0 14 0 0 0)
195 Hardware_ECC_Recovered  0x001a   043   030   000    Old_age   Always       -       21335218
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
240 Head_Flying_Hours       0x0000   100   253   000    Old_age   Offline      -       24078 (11 87 0)
241 Total_LBAs_Written      0x0000   100   253   000    Old_age   Offline      -       3555371798
242 Total_LBAs_Read         0x0000   100   253   000    Old_age   Offline      -       783085069

SMART Error Log Version: 1
ATA Error Count: 240 (device log contains only the most recent five errors)
	CR = Command Register [HEX]
	FR = Features Register [HEX]
	SC = Sector Count Register [HEX]
	SN = Sector Number Register [HEX]
	CL = Cylinder Low Register [HEX]
	CH = Cylinder High Register [HEX]
	DH = Device/Head Register [HEX]
	DC = Device Command Register [HEX]
	ER = Error register [HEX]
	ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 240 occurred at disk power-on lifetime: 17730 hours (738 days + 18 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 36 e4 9b 01  Error: UNC at LBA = 0x019be436 = 26993718

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 80 c0 38 96 e1 00      01:25:23.929  READ DMA EXT
  25 00 80 40 38 96 e1 00      01:25:23.910  READ DMA EXT
  25 00 80 c0 37 96 e1 00      01:25:23.910  READ DMA EXT
  25 00 80 40 37 96 e1 00      01:25:23.910  READ DMA EXT
  25 00 80 c0 36 96 e1 00      01:25:23.909  READ DMA EXT

Error 239 occurred at disk power-on lifetime: 17729 hours (738 days + 17 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 36 e4 9b 01  Error: UNC at LBA = 0x019be436 = 26993718

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 80 c0 24 9b e1 00      01:10:51.135  READ DMA EXT
  25 00 80 40 24 9b e1 00      01:10:51.124  READ DMA EXT
  25 00 80 c0 23 9b e1 00      01:10:51.124  READ DMA EXT
  25 00 80 40 23 9b e1 00      01:10:51.123  READ DMA EXT
  25 00 80 c0 22 9b e1 00      01:10:51.123  READ DMA EXT

Error 238 occurred at disk power-on lifetime: 17717 hours (738 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 36 e4 9b 01  Error: UNC at LBA = 0x019be436 = 26993718

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 08 30 e4 9b e1 00      00:45:16.331  READ DMA EXT
  25 00 08 28 e4 9b e1 00      00:45:16.281  READ DMA EXT
  35 00 08 ff ff ff ef 00      00:45:16.251  WRITE DMA EXT
  35 00 08 ff ff ff ef 00      00:45:16.249  WRITE DMA EXT
  35 00 08 ff ff ff ef 00      00:45:16.247  WRITE DMA EXT

Error 237 occurred at disk power-on lifetime: 17717 hours (738 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 36 e4 9b 01  Error: UNC at LBA = 0x019be436 = 26993718

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 20 20 e4 9b e1 00      00:45:13.254  READ DMA EXT
  35 00 18 ff ff ff ef 00      00:45:13.254  WRITE DMA EXT
  25 00 18 20 ec 9b e1 00      00:45:13.253  READ DMA EXT
  35 00 20 ff ff ff ef 00      00:45:13.253  WRITE DMA EXT
  35 00 20 ff ff ff ef 00      00:45:13.252  WRITE DMA EXT

Error 236 occurred at disk power-on lifetime: 17593 hours (733 days + 1 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 36 e4 9b 01  Error: UNC at LBA = 0x019be436 = 26993718

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 08 30 e4 9b e1 00      08:24:01.949  READ DMA EXT
  25 00 08 28 e4 9b e1 00      08:24:01.949  READ DMA EXT
  25 00 08 20 e4 9b e1 00      08:24:01.895  READ DMA EXT
  25 00 20 00 67 98 e1 00      08:24:01.833  READ DMA EXT
  25 00 20 ff ff ff ef 00      08:24:01.811  READ DMA EXT

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Download as text