Ubuntu Pastebin

Paste from weed at Sat, 2 May 2015 03:17:45 +0000

Download as text
  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.0-51-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.10
Device Model:     ST3750640AS
Serial Number:    5QD20ZYJ
Firmware Version: 3.AAE
User Capacity:    750,155,292,160 bytes [750 GB]
Sector Size:      512 bytes logical/physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA/ATAPI-7 (minor revision not indicated)
Local Time is:    Fri May  1 20:17:44 2015 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(  430) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 ( 202) minutes.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   103   086   006    Pre-fail  Always       -       6071011
  3 Spin_Up_Time            0x0003   094   093   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   097   097   020    Old_age   Always       -       3278
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   084   060   030    Pre-fail  Always       -       259499858
  9 Power_On_Hours          0x0032   075   075   000    Old_age   Always       -       22725
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       137
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   052   032   045    Old_age   Always   In_the_past 48 (109 223 65 41 0)
194 Temperature_Celsius     0x0022   048   068   000    Old_age   Always       -       48 (0 17 0 0 0)
195 Hardware_ECC_Recovered  0x001a   060   050   000    Old_age   Always       -       179431207
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x0000   100   253   000    Old_age   Offline      -       0
202 Data_Address_Mark_Errs  0x0032   100   253   000    Old_age   Always       -       0

SMART Error Log Version: 1
ATA Error Count: 16 (device log contains only the most recent five errors)
	CR = Command Register [HEX]
	FR = Features Register [HEX]
	SC = Sector Count Register [HEX]
	SN = Sector Number Register [HEX]
	CL = Cylinder Low Register [HEX]
	CH = Cylinder High Register [HEX]
	DH = Device/Head Register [HEX]
	DC = Device Command Register [HEX]
	ER = Error register [HEX]
	ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 16 occurred at disk power-on lifetime: 11908 hours (496 days + 4 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  10 51 01 ae 5e 54 e7

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  37 00 01 ae 5e 54 e7 00      04:27:37.428  SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  27 00 00 ae 5e 54 e0 00      04:27:37.369  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  37 00 00 ae 5e 54 e7 00      04:27:37.145  SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  27 00 01 ae 5e 54 e0 00      04:27:37.086  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  37 00 01 ae 5e 54 e7 00      04:27:35.000  SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]

Error 15 occurred at disk power-on lifetime: 11908 hours (496 days + 4 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  10 51 01 ae 5e 54 e7

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  37 00 01 ae 5e 54 e7 00      04:27:33.019  SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  27 00 00 ae 5e 54 e0 00      04:27:33.018  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  37 00 00 ae 5e 54 e7 00      04:27:33.018  SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  27 00 01 ef 66 54 e0 00      04:27:33.018  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  29 00 01 ef 66 54 e0 00      04:27:35.000  READ MULTIPLE EXT

Error 14 occurred at disk power-on lifetime: 11908 hours (496 days + 4 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  10 51 01 ae 5e 54 e7

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  37 00 01 ae 5e 54 e7 00      04:25:14.528  SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  27 00 00 ae 5e 54 e0 00      04:25:14.528  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  37 00 00 ae 5e 54 e7 00      04:25:14.528  SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  27 00 01 ae 5e 54 e0 00      04:25:18.947  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  37 00 01 ae 5e 54 e7 00      04:25:18.888  SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]

Error 13 occurred at disk power-on lifetime: 11908 hours (496 days + 4 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  10 51 01 ae 5e 54 e7

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  37 00 01 ae 5e 54 e7 00      04:25:14.528  SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  27 00 00 ae 5e 54 e0 00      04:25:14.528  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  37 00 00 ae 5e 54 e7 00      04:25:14.528  SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  27 00 01 ef 66 54 e0 00      04:25:14.527  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  29 00 01 ef 66 54 e0 00      04:25:14.527  READ MULTIPLE EXT

Error 12 occurred at disk power-on lifetime: 11904 hours (496 days + 0 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  10 51 01 ae 5e 54 e7

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  37 00 01 ae 5e 54 e7 00      03:08:45.731  SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  27 00 00 ae 5e 54 e0 00      03:08:45.506  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  37 00 00 ae 5e 54 e7 00      03:08:45.439  SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  27 00 01 ae 5e 54 e0 00      03:08:45.297  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  37 00 01 ae 5e 54 e7 00      03:08:45.172  SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%      7227         -
# 2  Short offline       Completed without error       00%      7207         -
# 3  Short offline       Completed without error       00%      7185         -
# 4  Short offline       Completed without error       00%      7165         -
# 5  Short offline       Completed without error       00%      7144         -
# 6  Short offline       Completed without error       00%      7123         -
# 7  Short offline       Completed without error       00%      7102         -
# 8  Short offline       Completed without error       00%      7081         -
# 9  Short offline       Completed without error       00%      7047         -
#10  Short offline       Completed without error       00%      7026         -
#11  Short offline       Completed without error       00%      7008         -
#12  Short offline       Completed without error       00%      6984         -
#13  Short offline       Completed without error       00%      6962         -
#14  Short offline       Completed without error       00%      6942         -
#15  Short offline       Completed without error       00%      6921         -
#16  Short offline       Completed without error       00%      6900         -
#17  Short offline       Completed without error       00%      6882         -
#18  Short offline       Completed without error       00%      6858         -
#19  Short offline       Completed without error       00%      6837         -
#20  Short offline       Completed without error       00%      6817         -
#21  Short offline       Completed without error       00%      7240         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.