Ubuntu Pastebin

Paste from root at Mon, 20 Apr 2015 12:31:08 +0000

Download as text
  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.0-49-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Maxtor DiamondMax 10 (ATA/133 and SATA/150)
Device Model:     Maxtor 6B300S0
Serial Number:    B607TF7H
Firmware Version: BANC1980
User Capacity:    300,090,728,448 bytes [300 GB]
Sector Size:      512 bytes logical/physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA/ATAPI-7 T13/1532D revision 0
Local Time is:    Mon Apr 20 14:31:08 2015 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		( 2283) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					No General Purpose Logging support.
Short self-test routine 
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 ( 118) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  3 Spin_Up_Time            0x0027   184   183   063    Pre-fail  Always       -       22518
  4 Start_Stop_Count        0x0032   253   253   000    Old_age   Always       -       79
  5 Reallocated_Sector_Ct   0x0033   253   253   063    Pre-fail  Always       -       0
  6 Read_Channel_Margin     0x0001   253   253   100    Pre-fail  Offline      -       0
  7 Seek_Error_Rate         0x000a   253   252   000    Old_age   Always       -       0
  8 Seek_Time_Performance   0x0027   250   232   187    Pre-fail  Always       -       65105
  9 Power_On_Minutes        0x0032   135   135   000    Old_age   Always       -       448h+07m
 10 Spin_Retry_Count        0x002b   253   252   157    Pre-fail  Always       -       0
 11 Calibration_Retry_Count 0x002b   253   252   223    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   253   253   000    Old_age   Always       -       110
192 Power-Off_Retract_Count 0x0032   253   253   000    Old_age   Always       -       0
193 Load_Cycle_Count        0x0032   253   253   000    Old_age   Always       -       0
194 Temperature_Celsius     0x0032   252   253   000    Old_age   Always       -       33
195 Hardware_ECC_Recovered  0x000a   253   252   000    Old_age   Always       -       19210
196 Reallocated_Event_Count 0x0008   253   253   000    Old_age   Offline      -       0
197 Current_Pending_Sector  0x0008   253   253   000    Old_age   Offline      -       0
198 Offline_Uncorrectable   0x0008   253   253   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0008   199   199   000    Old_age   Offline      -       0
200 Multi_Zone_Error_Rate   0x000a   253   252   000    Old_age   Always       -       0
201 Soft_Read_Error_Rate    0x000a   253   252   000    Old_age   Always       -       2
202 Data_Address_Mark_Errs  0x000a   253   252   000    Old_age   Always       -       0
203 Run_Out_Cancel          0x000b   253   252   180    Pre-fail  Always       -       2
204 Soft_ECC_Correction     0x000a   253   252   000    Old_age   Always       -       0
205 Thermal_Asperity_Rate   0x000a   253   252   000    Old_age   Always       -       0
207 Spin_High_Current       0x002a   253   252   000    Old_age   Always       -       0
208 Spin_Buzz               0x002a   253   252   000    Old_age   Always       -       0
209 Offline_Seek_Performnce 0x0024   239   239   000    Old_age   Offline      -       168
210 Unknown_Attribute       0x0032   253   252   000    Old_age   Always       -       0
211 Unknown_Attribute       0x0032   253   252   000    Old_age   Always       -       0
212 Unknown_Attribute       0x0032   253   253   000    Old_age   Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%     34461         -
# 2  Short offline       Completed without error       00%     34438         -
# 3  Short offline       Completed without error       00%     34414         -
# 4  Extended offline    Interrupted (host reset)      10%     34391         -
# 5  Short offline       Completed without error       00%     34366         -
# 6  Short offline       Completed without error       00%     34342         -
# 7  Short offline       Completed without error       00%     34318         -
# 8  Short offline       Completed without error       00%     34294         -
# 9  Short offline       Completed without error       00%     34270         -
#10  Short offline       Completed without error       00%     34246         -
#11  Short offline       Completed without error       00%     34199         -
#12  Short offline       Completed without error       00%     34175         -
#13  Short offline       Completed without error       00%     34151         -
#14  Short offline       Completed without error       00%     34127         -
#15  Short offline       Completed without error       00%     34103         -
#16  Short offline       Completed without error       00%     34079         -
#17  Extended offline    Completed without error       00%     34057         -
#18  Short offline       Completed without error       00%     34031         -
#19  Short offline       Completed without error       00%     33650         -
#20  Short offline       Completed without error       00%     33626         -
#21  Short offline       Completed without error       00%     33602         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Download as text