Ubuntu Pastebin

Paste from bev at Sun, 8 Mar 2015 23:04:17 +0000

Download as text
  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
smartctl 6.2 2013-07-26 r3841 [i686-linux-3.13.0-44-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     SAMSUNG SpinPoint P80
Device Model:     SAMSUNG SP1604N
Serial Number:    S013J10Y247714
Firmware Version: TM100-24
User Capacity:    160,041,885,696 bytes [160 GB]
Sector Size:      512 bytes logical/physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA/ATAPI-7 T13/1532D revision 0
Local Time is:    Sun Mar  8 19:04:16 2015 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00)	Offline data collection activity
					was never started.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		( 5760) seconds.
Offline data collection
capabilities: 			 (0x1b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					No Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					No General Purpose Logging support.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 (  96) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   100   100   051    Pre-fail  Always       -       5
  3 Spin_Up_Time            0x0007   067   056   000    Pre-fail  Always       -       5760
  4 Start_Stop_Count        0x0032   099   099   000    Old_age   Always       -       1918
  5 Reallocated_Sector_Ct   0x0033   253   253   010    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000b   253   253   051    Pre-fail  Always       -       0
  8 Seek_Time_Performance   0x0024   253   253   000    Old_age   Offline      -       0
  9 Power_On_Half_Minutes   0x0032   092   092   000    Old_age   Always       -       40503h+20m
 10 Spin_Retry_Count        0x0013   253   253   049    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   099   099   000    Old_age   Always       -       1087
194 Temperature_Celsius     0x0022   157   082   000    Old_age   Always       -       27
195 Hardware_ECC_Recovered  0x000a   100   100   000    Old_age   Always       -       160201014
196 Reallocated_Event_Count 0x0012   099   099   000    Old_age   Always       -       4
197 Current_Pending_Sector  0x0033   253   253   010    Pre-fail  Always       -       0
198 Offline_Uncorrectable   0x0031   099   099   010    Pre-fail  Offline      -       4
199 UDMA_CRC_Error_Count    0x000b   100   100   051    Pre-fail  Always       -       0
200 Multi_Zone_Error_Rate   0x000b   100   100   051    Pre-fail  Always       -       0
201 Soft_Read_Error_Rate    0x000b   100   100   051    Pre-fail  Always       -       0

SMART Error Log Version: 1
ATA Error Count: 78 (device log contains only the most recent five errors)
	CR = Command Register [HEX]
	FR = Features Register [HEX]
	SC = Sector Count Register [HEX]
	SN = Sector Number Register [HEX]
	CL = Cylinder Low Register [HEX]
	CH = Cylinder High Register [HEX]
	DH = Device/Head Register [HEX]
	DC = Device Command Register [HEX]
	ER = Error register [HEX]
	ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 78 occurred at disk power-on lifetime: 40503 hours (1687 days + 15 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  04 51 fe 00 00 00 40  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  ef 05 fe 00 00 00 40 00      00:00:41.750  SET FEATURES [Enable APM]
  c8 00 20 b0 2d ca ef 00      00:00:41.750  READ DMA
  c8 00 08 78 97 be ef 00      00:00:41.625  READ DMA
  c8 00 48 c8 2e ca ef 00      00:00:41.625  READ DMA
  c8 00 08 18 8c fb ef 00      00:00:41.563  READ DMA

Error 77 occurred at disk power-on lifetime: 40501 hours (1687 days + 13 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  04 51 fe 00 00 00 40  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  ef 05 fe 00 00 00 40 00      00:07:16.500  SET FEATURES [Enable APM]
  c8 00 08 80 50 43 e9 00      00:07:16.500  READ DMA
  c8 00 00 e8 9a 9c e9 00      00:07:16.438  READ DMA
  ca 00 08 40 98 c5 ed 00      00:07:16.375  WRITE DMA
  ca 00 30 10 98 c5 ed 00      00:07:16.375  WRITE DMA

Error 76 occurred at disk power-on lifetime: 40501 hours (1687 days + 13 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  04 51 fe 00 00 00 40  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  ef 05 fe 00 00 00 40 00      00:00:38.875  SET FEATURES [Enable APM]
  c8 00 00 e8 7a 5a ee 00      00:00:38.875  READ DMA
  c8 00 10 d0 a1 3e ee 00      00:00:38.750  READ DMA
  ca 00 08 10 60 fe ef 00      00:00:38.688  WRITE DMA
  ca 00 08 08 58 fe ef 00      00:00:38.625  WRITE DMA

Error 75 occurred at disk power-on lifetime: 40501 hours (1687 days + 13 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  04 51 fe 00 00 00 40  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  ef 05 fe 00 00 00 40 00      00:00:46.563  SET FEATURES [Enable APM]
  c8 00 48 30 2e ca ef 00      00:00:46.500  READ DMA
  c8 00 08 78 97 be ef 00      00:00:46.313  READ DMA
  c8 00 08 28 5e 7b ee 00      00:00:46.000  READ DMA
  c8 00 08 38 d0 7e ee 00      00:00:45.938  READ DMA

Error 74 occurred at disk power-on lifetime: 40501 hours (1687 days + 13 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  04 51 fe 00 00 00 40  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  ef 05 fe 00 00 00 40 00      00:00:45.375  SET FEATURES [Enable APM]
  c8 00 08 78 97 be ef 00      00:00:45.250  READ DMA
  c8 00 20 b0 2d ca ef 00      00:00:45.125  READ DMA
  c8 00 48 c8 2e ca ef 00      00:00:45.000  READ DMA
  c8 00 08 18 8c fb ef 00      00:00:45.000  READ DMA

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%      3312         -

Selective Self-tests/Logging not supported
Download as text