1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174 | smartctl 6.2 2013-07-26 r3841 [i686-linux-3.13.0-44-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SAMSUNG SpinPoint P80
Device Model: SAMSUNG SP1604N
Serial Number: S013J10Y247714
Firmware Version: TM100-24
User Capacity: 160,041,885,696 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 T13/1532D revision 0
Local Time is: Sun Mar 8 19:04:16 2015 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 5760) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 96) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 051 Pre-fail Always - 5
3 Spin_Up_Time 0x0007 067 056 000 Pre-fail Always - 5760
4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 1918
5 Reallocated_Sector_Ct 0x0033 253 253 010 Pre-fail Always - 0
7 Seek_Error_Rate 0x000b 253 253 051 Pre-fail Always - 0
8 Seek_Time_Performance 0x0024 253 253 000 Old_age Offline - 0
9 Power_On_Half_Minutes 0x0032 092 092 000 Old_age Always - 40503h+20m
10 Spin_Retry_Count 0x0013 253 253 049 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 1087
194 Temperature_Celsius 0x0022 157 082 000 Old_age Always - 27
195 Hardware_ECC_Recovered 0x000a 100 100 000 Old_age Always - 160201014
196 Reallocated_Event_Count 0x0012 099 099 000 Old_age Always - 4
197 Current_Pending_Sector 0x0033 253 253 010 Pre-fail Always - 0
198 Offline_Uncorrectable 0x0031 099 099 010 Pre-fail Offline - 4
199 UDMA_CRC_Error_Count 0x000b 100 100 051 Pre-fail Always - 0
200 Multi_Zone_Error_Rate 0x000b 100 100 051 Pre-fail Always - 0
201 Soft_Read_Error_Rate 0x000b 100 100 051 Pre-fail Always - 0
SMART Error Log Version: 1
ATA Error Count: 78 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 78 occurred at disk power-on lifetime: 40503 hours (1687 days + 15 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 51 fe 00 00 00 40 Error: ABRT
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
ef 05 fe 00 00 00 40 00 00:00:41.750 SET FEATURES [Enable APM]
c8 00 20 b0 2d ca ef 00 00:00:41.750 READ DMA
c8 00 08 78 97 be ef 00 00:00:41.625 READ DMA
c8 00 48 c8 2e ca ef 00 00:00:41.625 READ DMA
c8 00 08 18 8c fb ef 00 00:00:41.563 READ DMA
Error 77 occurred at disk power-on lifetime: 40501 hours (1687 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 51 fe 00 00 00 40 Error: ABRT
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
ef 05 fe 00 00 00 40 00 00:07:16.500 SET FEATURES [Enable APM]
c8 00 08 80 50 43 e9 00 00:07:16.500 READ DMA
c8 00 00 e8 9a 9c e9 00 00:07:16.438 READ DMA
ca 00 08 40 98 c5 ed 00 00:07:16.375 WRITE DMA
ca 00 30 10 98 c5 ed 00 00:07:16.375 WRITE DMA
Error 76 occurred at disk power-on lifetime: 40501 hours (1687 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 51 fe 00 00 00 40 Error: ABRT
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
ef 05 fe 00 00 00 40 00 00:00:38.875 SET FEATURES [Enable APM]
c8 00 00 e8 7a 5a ee 00 00:00:38.875 READ DMA
c8 00 10 d0 a1 3e ee 00 00:00:38.750 READ DMA
ca 00 08 10 60 fe ef 00 00:00:38.688 WRITE DMA
ca 00 08 08 58 fe ef 00 00:00:38.625 WRITE DMA
Error 75 occurred at disk power-on lifetime: 40501 hours (1687 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 51 fe 00 00 00 40 Error: ABRT
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
ef 05 fe 00 00 00 40 00 00:00:46.563 SET FEATURES [Enable APM]
c8 00 48 30 2e ca ef 00 00:00:46.500 READ DMA
c8 00 08 78 97 be ef 00 00:00:46.313 READ DMA
c8 00 08 28 5e 7b ee 00 00:00:46.000 READ DMA
c8 00 08 38 d0 7e ee 00 00:00:45.938 READ DMA
Error 74 occurred at disk power-on lifetime: 40501 hours (1687 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 51 fe 00 00 00 40 Error: ABRT
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
ef 05 fe 00 00 00 40 00 00:00:45.375 SET FEATURES [Enable APM]
c8 00 08 78 97 be ef 00 00:00:45.250 READ DMA
c8 00 20 b0 2d ca ef 00 00:00:45.125 READ DMA
c8 00 48 c8 2e ca ef 00 00:00:45.000 READ DMA
c8 00 08 18 8c fb ef 00 00:00:45.000 READ DMA
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 3312 -
Selective Self-tests/Logging not supported
|